Lincoln sp 125 plus problems - Quality of work comes before profit! Old Fashion "Customer is always right policy". 1 year warranty. Fair Estimates on all Lincoln units. Low Prices. To have your Lincoln unit repaired/tested call 1- (336)-969-0110. Make. Part Number. Model Number.

 
I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.. Katie o

Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.1994 lincoln town car. radio and power antenna don't work. fuses are good everything else works. what is the problem? ... lincoln sp 125 plus glowworm 30 cxi ...Lincoln Electric is one of the world's largest manufacturers of industrial welding supplies, and WeldingMart is the largest online Lincoln welder parts dealer. We also carry a selection of parts from Miller Electric. Whether you're repairing an older welder or upgrading a new one, our high-quality welder parts and service will help make it happen.Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding Guns1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Nov 25, 2011 · Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool. Premium quality 100Amp replacement MIG gun stinger torch, 10-foot (3m) cable, fully compatible with Lincoln Magnum 100L (K530-5) Usually Lincoln Magnum 100L (K530-5) MIG gun can be found on SP-85, SP-100, SP-100I, SP-100T, SP-125 Plus, SP-130T, SP-135 Plus, SP-140I, SP-155, SP-170, SP-170I, SP-170T, SP-175 Plus, SP-175T, Handy MIG 170I, MIG Pak 10, MIG Pak 15, Pro 100, Pro 155, Pro-Core 100 ...Contact us by phone at 888-935-3877. Service & Distributor Locator. Print & Pdf Publications: REQUEST LITERATURE. COUNTERTOP PARTS GUIDE. (20 mb PDF) service navigator: video tips.lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderIt works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?If you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusPAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro...If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusIt doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantLincoln Electric: Forney: Lincoln Electric: Name: 120-Volt 140 Amp Easy Weld FC-i Flux Core Gasless Welder: 125 Amp Weld-Pak 125 Flux-Core Wire Feed Welder, 115V (No Gas) 140 Amp 120-Volt MIG Welder: Weld-Pak 180 Amp MIG Flux-Core Wire Feed Welder, 230V, Aluminum Welder with Spool Gun sold separately: Price $(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.Need some help with my "new to me" welder. I am having problems with my welder, its a Lincoln SP250 welder (ditigal version). I am getting a lot of sticking and "blast off" with weld porosity. The weld are are narrow and ropy, the gun are "kicking" back at me. I changed the liner, tip and nozzle. I am using .35 solid steel with 75/25 Argon/CO2.lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderI was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Lincoln ElectricLincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.Drive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusDrive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantRe: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantHome › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsPAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Need some help with my "new to me" welder. I am having problems with my welder, its a Lincoln SP250 welder (ditigal version). I am getting a lot of sticking and "blast off" with weld porosity. The weld are are narrow and ropy, the gun are "kicking" back at me. I changed the liner, tip and nozzle. I am using .35 solid steel with 75/25 Argon/CO2.SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.Welding Equipment; Cutting Equipment; Gear & Tools; Accessories; Welding Wire, Flux & Rods; Guns & Torches; Automated Welding & Cutting Systems; Training Equipment for Educators02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Drive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.Opinions on 305G Lincoln; Best engine Drive under 5000$ SP-125 Plus Amperage Question; Oil Fill on Perkins engine for Lincoln 300D; help..need parts for SA 200; Wire burning before touching metal; SP 250 stutter; SA-200 Engine Frozen; Invertec Questions; Newbie here with a dumb question; Power Mig 180C pricing? Brand new Lincoln Pro 180 for ...Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Lincoln ElectricI was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.

This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.. Zdxwafcv6p9

lincoln sp 125 plus problems

Nov 25, 2011 · Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool. Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.Wire welder feed, but no arc (spark) 10-20-2012, 08:43 PM. I have a millermatic 150 that I bought used a few years ago. It has been an amazing welder. I was welding the other day and in the middle of a bead, it stopped welding. I have had this happen before and waited to let it cool and continued on.Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about..

Popular Topics